Return Loss Measurement Range: 0 dB to > 30 dB
Display Modes Line (L)
Memory (M)
Comparison (L & M)
Difference (L-M)
Memories 15 - Stores trace displayed in Mode L.
Interface RS232 to printer or PC.
Connector 9 pin D Male.
Configuration 4800 baud, no parity, 8 bits, 1 stop bit.
PIN FUNCTION DIRECTION
2 Received Data (RXD) Input
3 Transmit Data (TXD) Output
5 Ground
6 Data Set Ready (DSR) Input
7 Request To Send (RTS) Output
Display 240 x 128 pixel LCD
240 x 100 pixel waveform area
Radiodetection Ltd. 00901209-6
T631 OPERATING MANUAL 48