Details the different ports available on the balance for connecting external devices.
Specifies the primary purpose of the balance for determining weighing values in a laboratory.
Specifies ideal locations and conditions for balance setup, avoiding vibrations and dust.
Initiates the immediate adjustment or calibration process.
Essential steps and precautions for ensuring long-lasting use and reliable measurements.
Procedure for setting the balance to a zero mass indication.
Method for determining the net weight of an object by excluding container mass.
Configuration options for the weighing mode, including filters and autozero.
Function for assessing balance operation and diagnosing errors through automated testing.
Procedure for automatic and manual internal calibration of the balance.
Detailed steps for performing manual internal and external balance adjustments.
Procedure for adjusting the balance using external standard weights.
Process for user-defined calibration using external weights within the balance range.
Management of user accounts, including name, password, access level, and language.
Procedure for archiving balance data (weighments, users, products) to external memory.
Method for transferring saved data from external memory to the balance.
Function for counting small objects based on the mass of a sample piece.
Mode for checking if sample mass falls within predefined low and high thresholds.
Mode for weighing samples until a target mass is reached with defined tolerance.
Calculates and displays mass deviation percentage relative to a standard.
Mode optimized for determining mass of objects in motion, often requiring special filtering.
Function to determine the density of solid materials using an optional kit.
Function to determine the density of liquids using an optional kit and sinker.
Collects and analyzes data from series of measurements to generate statistical reports.
Allows weighing individual ingredients and summing their total mass.
Function to register and hold the highest mass value during a weighing process.
Procedure for calibrating pipettes by determining accuracy and repeatability errors.
Configuration of serial communication ports, including baud rate and parity.
Settings for establishing a wireless network connection for the balance.
Settings for connecting and communicating with a computer via COM or USB ports.
Configuration for connecting and sending data to a printer.
A comprehensive list of commands for controlling the balance via RS232 interface.
Kit for determining density of solids and liquids, applicable to balances with 1 mg resolution.