3.8.2.1  In-Band Signaling of PTT with Different Audio Tones 
Setting using  
the R&S ZS 4200 
1.  Set the “PTT Signaling” parameter to “Enable” on the radio. 
2.  Set the “PTT Signaling Frequency” parameter to a value of   
2040 Hz, 2300 Hz, 2970 Hz or 3100 Hz. 
3.  Set the “PTT Signaling Threshold” parameter related to the TX audio 
level. 
3.8.2.2  In-Band Signaling of SQ with Different Audio Tones  
Setting using  
the R&S ZS 4200 
1.  Set the “SQ/RSSI Signaling” parameter to “SQ”, or “INVSQ” on the 
radio. 
2.  Set the “SQ Signaling Frequency” parameter to a value of 1225 Hz, 
2040 Hz, 2175 Hz, 2440 Hz, 2970 Hz or 3300 Hz. 
3.  Set the “SQ/RSSI Signaling Level” parameter related to the RX audio 
level. 
3.8.2.3  Audio In-Band Tones for RSSI Signaling 
Setting using  
the R&S ZS 4200 
1.  Set the “SQ/RSSI Signaling” parameter to “RSSI” on the radio. 
2.  Set the “SQ/RSSI Signaling Level” parameter to configure the tone 