R&S XU 4200 Audio via VoIP (Optional)
6166.5368.02.01 3.106
3.15.2 Cabling
Instructions
1. Connect the radio via the connectors X6 and X9 to the LAN network.
Cabling
Fig. 3.94 VoIP cabling.
3.15.3 Configuration
VoIP interface
configuration using
the R&S ZS 4200
Use the Service and Maintenance Tool R&S ZS 4200 to configure the VoIP
interface.
1. Set the “Select Audio Interface” parameter on the radio to “VoIP”.
2. Configure the “VoIP radio URI TX“.
3. Configure the “VoIP radio URI RX“.
4. Configure the “Emergency VoIP URI ACL”.
5. Configure the “Normal VoIP URI ACL”.
6. Configure the “TX Audio ALC VoIP” and adjust the
“TX Audio Level VoIP” as required in your VoIP audio infrastructure.
Note: The default settings (see chapter 3.3.1) ensures the compliance with
the ED-137 requirement of 30 % AM modulation depth at 10 dBm0 audio
level. If the VoIP infrastructure complies with the ED-137, the default value
shall be left unchanged.
7. Configure the “VoIP PTT Summation Mode“.
8. Configure the “VoIP Jitter Buffer Prefetch Value”.
9. Configure the “RX Audio AGC VoIP” and adjust the
“RX Audio Level VoIP” as required in your VoIP audio infrastructure.
Note: The default settings (see chapter 3.3.1) ensures the compliance
with the ED-137 requirement of 10 dBm0 at 30% AM modulation depth. If
the VoIP infrastructure complies with the ED-137, the default value shall be
left unchanged.