R&S XU 4200  Troubleshooting 
6166.5368.02.01 4.16   
 
4.2.2 RX CBIT Events 
Code Message Level Config Note  Action 
0101  INACTIVE WARNING  W  W  Radio was switched to 
the inactive mode, e.g. 
via the *OFF contact on 
the rear panel or by 
software command or 
locally on the radio (see 
chapter 3.4.7.2). 
Not
e: If the radio 
swit
ches into INACTIVE 
mode, all active VoIP 
connections will be 
terminated and new 
VoIP connection 
requests will be 
rejected. 
Check the VOP LED (see 
chapter 4.1.2). 
Che
ck the hardware 
input *OFF on
 connector 
X10.7. 
Check software settings. 
0102  NOGO ERROR  E  –  Radio switches to the 
NOGO state. 
The NOGO error is the 
general fault in the 
radio and corresponds 
to the GO LED. At least 
one error or one NOGO 
warning exists. 
Check the NOGO 
configuration via service 
PC (see chapter 3.3). 
Analyze the 
CBIT status 
in detail in order to find 
out what the fault actually 
is. 
0103  MAIN FAN WARNING  W  N  Rotation speed of the 
main fan is low. 
Check airflow of fans and 
clear the ventilation 
opening. 
Check the internal 
temperatures in the radio 
(see chapter 3.4.7.4.3) to 
determine whether 
operation can be 
maintained for a certain 
time (see chapter 5.2). 
If this fails to eliminate 
the fault, send the radio 
to service. 
0104  MAIN FAN ERROR  E  –  Main fan is not running 
or is blocked. 
Send the radio to service.
0107  MMI WD Restart  W  –  Indication of restart 
after the watch-dog 
timer expires. 
This maybe a software 
error. Please report it to 
the service. Radio will be 
restarted automatically. 
0109  MODE IMPOSSIBLE  W  –  Operating modes of the 
receiver module and 
transmitter module do 
not fit together or mode 
setting failed. 
Please retry to setup the 
modes. If this fails to 
eliminate the problem, 
this might be a software 
error. Please report it to 
the service.