Visual Inspection  R&S XU 4200 
 4.3 6166.5368.02.01 
Indication  Possible cause of fault  Remedy 
LED GO 
not illuminated 
CBIT detected error 
(At least one CBIT error or NOGO 
warning exists in the radio.) 
Check CBIT status 
Check NOGO configuration via  
service PC 
Check radio environment (antenna, 
DC voltage) 
LED VOP 
not illuminated 
Radio set to "OFF" 
(standby operation). Display shows 
INACT in standard operating display.
 
Hardware input *OFF on rear panel 
connector X5.7 or X10.7 is 
connected to ground. 
Radio was switched off remotely via 
remote control command or locally 
via front panel of the radio. 
Activate radio using a proper remote 
control command or switch over to 
active mode locally (see chapter 
3.4.7.2) 
Che
ck hardware Input *OFF on 
con
nector X5.7 or X10.7 if a  
contact to ground is applied. 
Activate radio using a proper remote 
control command or switch over to 
active mode locally. 
4.1.3  Checking the CBIT State 
Displayed warnings 
and/or error 
messages 
For detection of device and system failures, continuous built-in test (CBIT) 
functions are implemented in the equipment. 
  The CBIT starts directly after switching on the transceiver 
  Warnings and/or error messages produced during ongoing operation 
are displayed in the CBIT STATUS menu (see chapter 3.4.7.5) 
Whe
n malfunctions (warning or erro
r message) are detected, the failure 
is signalled to the connected remote control unit. 
CBIT always indicates the existing state, which means that as long as a 
message is being indicated by CBIT, this problem persists.