Interface Description  R&S XU 4200 
 6.9 6166.5368.02.01 
6.2.8  RX Input X8 
BNC-type female 
 
Fig. 6.8  RX input X8. 
Entry in column D (direction): O =  Output  I =  Input    B = Bi-directional 
Entry in column T (type):  A = Analog  D = Digital  P = Power
 
Signal description  D  T  Range  Contact  Remarks 
RX Input  I  A  107 up to +7 dBm 
Sensitivity Low 
Noise LN: 
< 105 dBm for 112 
MHz to 118 MHz 
< 107 dBm for 118 
MHz to 144 MHz 
< 105 dBm for 144 
MHz to 156 MHz 
(S+N)/N = 10 dB 
weighted ITU-T, 
mod. depth 30 %, 
AF = 1 kHz 
Sensitivity Low 
Distortion LD: 
< 99 dBm for 112 
MHz to 118 MHz 
< 101 dBm for 118 
MHz to 144 MHz 
< 99 dBm for 144 
MHz to 156 MHz 
(S+N)/N = 10 dB 
weighted ITU-T, 
mod. depth 30 %, 
AF = 1 kHz 
X8.1  112 to 155.991666 MHz 
 
Sensitivity LN/LD  
configurable via software 
GND   –  A  –  X8.2   
 
 
Ethernet – LAN Remote Control X9\Ethernet – LAN Remote Control X9 "Radio".doc