EasyManua.ls Logo

R&S ZNA26 - Page 1441

R&S ZNA26
1709 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command reference
R&S
®
ZNA
1441User Manual 1178.6462.02 ─ 20
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:CFACtor........................................1448
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:FLATness..................................... 1448
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:METHod....................................... 1449
SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect:RRECeiver....................................1450
SOURce:POWer:CORRection:COLLect:VNETworks....................................................... 1450
SOURce<Ch>:POWer<PhyPt>:CORRection:DATA:PARameter<Wv>:COUNt?...................1451
SOURce<Ch>:POWer<PhyPt>:CORRection:DEFault......................................................1451
SOURce<Ch>:POWer<PhyPt>:CORRection:FAST..........................................................1452
SOURce<Ch>:POWer<PhyPt>:CORRection:GENerator<Gen>[:STATe]............................ 1452
SOURce<Ch>:POWer:CORRection:IMODulation:METHod.............................................. 1453
SOURce<Ch>:POWer<PhyPt>:CORRection:IMODulation:LTONe[:ACQuire]......................1453
SOURce<Ch>:POWer<PhyPt>:CORRection:IMODulation:UTONe[:ACQuire].....................1454
SOURce<Ch>:POWer<PhyPt>:CORRection:NREadings................................................. 1455
SOURce<Ch>:POWer<PhyPt>:CORRection:OSOurces[:STATe].......................................1455
SOURce:POWer:CORRection:PPOWer......................................................................... 1456
SOURce:POWer:CORRection:PPOWer:PATTenuation.....................................................1456
SOURce<Ch>:POWer<PhyPt>:CORRection:PSELect.....................................................1456
SOURce<Ch>:POWer<PhyPt>:CORRection:STATe........................................................ 1457
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient[:STATe]....................................1457
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:CALibration..............................1458
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:COUNt?...................................1459
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:DEFine<ListNo>....................... 1459
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:DELete<ListNo>:ALL................ 1460
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:DELete<ListNo>[:DUMMy].........1460
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:FEED...................................... 1461
SOURce<Ch>:POWer<PhyPt>:CORRection:TCOefficient:INSert<ListNo>.........................1461
SOURce:POWer:CORRection:PMETer:ID <PowerMeter>
Selects an external power meter for the scalar source power calibration (flatness cali-
bration).
Note: The command cannot be used unless a power meter is connected via GPIB bus,
USB or LAN interface and configured in the "External Power Meters" dialog.
Parameters:
<PowerMeter> Number of external power meter. The parameters UP, DOWN,
MIN, MAX are not available for this command.
Range: 1 to number of configured external power meters
*RST: The power meter selection is not changed by a
reset of the analyzer.
Example: See SOURce<Ch>:POWer<PhyPt>:CORRection:COLLect[:
ACQuire] on page 1587
Manual operation: See "Power Meter" on page 574
SOURce:POWer<PhyPt>:CORRection:SLEVeling:DELete
Removes the (global) leveling dataseet of port <PhyPt>.