Steam mode
33 / 107
In the “steam” cooking mode, the steam generator generates hygienic fresh steam. You can
set the cooking cabinet temperature from 30 °C to 130 ℃ .
Cooking methods: Steaming, stewing, blanching, simmering, soaking, vacuum cooking,
thawing, preserving
step info/button instructions
1 Choose the “steam” mode.
2
To preheat, turn the selection button anti-
clockwise as far as it will go. “PreEH” is shown
on the display. The end of preheating is
indicated by an acoustic signal and “LoAd” on
the display.
3
Set the required temperature. The standard
value is boiling temperature.
4 Press the button to set the cooking time.
5
Set the required cooking time e.g. 1 h and 6
min. For continuous operation turn the selection
button clockwise as far as it will go.
4
Or alternatively press the “core temperature”
button and set the required core temperature.
5 Choose the required core temperature.

Other manuals for Rational COMBIMASTER

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational COMBIMASTER and is the answer not in the manual?

Rational COMBIMASTER Specifications

General IconGeneral
ManufacturerRational
CategoryOven
TypeCombi Oven
CleaningAutomatic cleaning system
Power ConsumptionVaries by model
Steam InjectionYes
DimensionsVaries by model
WeightVaries by model
Temperature Range30-300°C
Cooking ModesConvection, steam, combination
Capacity10-20 gastronorm containers

Related product manuals