EasyManua.ls Logo

Rational SelfCookingCenter XS UV - Equipotential Bonding; Connection Values

Rational SelfCookingCenter XS UV
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
6 Electrical connection
6.3 Equipotential bonding
A connection site for optional equipotential bon-
ding is located on the bottom or the back of the
device.
6.4 Connection values
SCC, CM_P
Power [kW] /
Current consumption [A]
Fuse [A]
3 AC 200V 5,3 / 15,4 16
3 AC 230V 5,70 / 14,5 16
3 NAC 400V 5,7 / 8,5 10
3 NAC 415V 6,2 / 8,7 10
1 NAC 230V 5,3/22,9 25
1 NAC 240V 5,7/24 25
2 AC 230V 5,3/22,9 25
2 AC 240V 5,7 / 24 25
Maximum permissible tolerance for input voltage (see type label for input voltage) is
within the range of -15% to + 10%.

Related product manuals