EasyManuals Logo

Ravaglioli GP3.140RS User Manual

Ravaglioli GP3.140RS
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
GB
Page 28 of 60
INSTRUCTION, USE AND
MAINTENANCE MANUAL
Fig. 45
2
516 5 34
7
KEY
1 1
st
weight fitting point distance
2 Rim diameter
3 Balancing mode
4 Point at which to take the measure/adhesive
weight fitting
5 Point at which to take the measure/clip weight
fitting
6 Last unbalance detected by the machine
7 Rim width
14.3 Indicative display of points where to
detect measures/to fit weight
IT IS VERY IMPORTANT TO RE-
MEMBER THE POINTS SELECTED
FOR MEASUREMENT INSIDE THE
RIM SINCE DURING THE WEIGHTS
FITTING WITH FIXED LASER YOU
WILL NOT HAVE ANY OTHER
REFERENCE EXCEPT FOR THE
CROSS LINE ON THE RIM, GEN-
ERATED BY THE LASER ITSELF.
THE POSITIONING IN DEPTH WILL
BE AT THE DISCRETION OF THE
OPERATOR.
Depending on the type of program selected,the machine
shows on the monitor the guideline points where to
take measures and, consequently, where you must
apply weights (Fig. 45 ref. 4-5).
THE MORE THE POINTS CHOSEN
FOR THE PROBING ARE DISTANT
FROM EACH OTHER THE MORE
THE BALANCING WILL BE EFFEC-
TIVE.
14.3.1 Weights positioning
The monitor displays when it is absolutely necessary
that the weight is applied at "12 o'clock" position. Pay
particular attention to the content of the weights iden-
tification icons since if the following words are
displayed, then the icon corresponding weight has to
be applied at "12 o'clock" position (typical of ALU-S1,
ALU-S2 programs).
IF ALL MEASURES REQUIRED BY
THE PROGRAM HAVE NOT BEEN
TAKEN/INSERTED, THE MACHINE
DOES NOT ALLOW THE WHEEL
SPIN TO DETECT THE UNBAL-
ANCE.
14.4 Displaying the active/modifiable field
During the various phases of measures detection, the
active field turns blue.
Pressing the buttons or you can change
the value and/or program inside the active field. To
change the selected active field, simply press the button
until the desired field is coloured blue.
THE SELECTION OF THE ACTIVE
FIELD IS DONE BY HIGHLIGHT-
ING THE FIELDS IN A CLOCKWISE
DIRECTION.
G3.140R - GP3.140R - G3.140RS - GP3.140RS
RAVAGLIOLI S.p.A.
1297-M007-1_R

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ravaglioli GP3.140RS and is the answer not in the manual?

Ravaglioli GP3.140RS Specifications

General IconGeneral
BrandRavaglioli
ModelGP3.140RS
CategoryWheel Balancers
LanguageEnglish

Related product manuals