User and maintenance manual for stoves with RDS technology
Pag.30
01/02/2016
8.7 Operating precautions
• In case of faulty operation turn the stove o󰀨 pressing button no. 3.
• Do not manually load the re pot with pellets.
Any build up of unburned pellets inside the re pot after repeatedly trying to light the stove, must be removed before further
attempts.
• Do not use any fuels other than wood pellets.
• Should the ignition system be faulty, do not attempt to light the stove using ammable materials.
8.8. Remote control (only for free standing stoves)
IR receiver for remote control (12 volts batteries code LRV08 not included)
• P1 - P2 Set temperature :
allows to set the desired value for the room
temperature from 44 °F to 104 °F and set “EST“ or
“MAN”
P4 - P5 Set power :
allows to set the working power between a range of
minimum 1 to maximum 5
• OK : by keeping pressed for 3 second longs it allows the
manual switch on and o󰀨 of the stove
.
BASIC FUNCTIONS
• OK multifunction : if you press one time you can enter in the main menu
and the conrmation of the setting. It is possible to
exit step by step from each menu by keeping pressed
each time.
• P1 - P4
multifunction
:
to scroll the icons in the menu
P2 - P5
multifunction
: to modify the setting in the menu
ADVANCED FUNCTIONS
PHASE DESCRIPTION
FINAL CLEANING The stove is switching o󰀨, the cooling phase is not yet completed.
IGNITION The ignition phase has started,the pellets are loaded into rebox.
WAITING FOR FLAME The pellet is lighted by the hot air passing trought the electrical igniter.
FLAME PRESENT The ame is visibile in the re pot.
WORKING The stove completed switch ON phase; you can change power.
MODULATION WORKING The room temperature set has been reached.
ECO STOP Comfort Climate activated, temperature set has been reached; the stove is o󰀨.
T ON The room sensor is o󰀨 or an external thermostat has been connected.
COOLING/WAITING FOR
START
The stove is cooling DOWN:when stove is cooled down can start automatically.
COOLING/WAITING FOR
RESTART
The stove is in the cooling DOWN: when the stove is cooled down can restart automatically.
ON/WAITING FOR RE-
START
The switch ON phase, when the stove is warm, started. The operation is same of phase ON
HOT SMOKE The max temperature of smokes is reached: to reduce temperature, feeding pellets and air draft redu-
ce at POWER 01.
OFF The stove is o󰀨.
8.9. Synthetic table of phases

Table of Contents

Other manuals for Ravelli SPILLO

Related product manuals