Depressing this key after selecting BOOM CAL selects the last boom number.
EXAMPLE: b-02 will decrease to b-01.
Entering the calculated Boom Cal data:
a) Select desired boom number.
b) Enter boom length as determined in section "CALCULATING BOOM CAL".
c) If a boom is not needed or used, enter a "0" for the length.
10) Enter SPEED CAL in
.
11) Enter METER 1 CAL calibration number in
.
12) Enter METER 2 CAL calibration number in the
. If only one product is being used, enter "0".
13) Enter VALVE 1 CAL calibration number in .
14) Enter VALVE 2 CAL calibration number in
. If only one product is being used, enter "0".
15) Enter PROD 1 CAL Target Application Rate
.
NOTE: A decimal point is automatically shown in the display window. Therefore, 20
ounces per acre is entered as "2""0""0", but shown as "20.0".
16) Enter PROD 2 CAL Target Application Rate, in
. If only one product is being used, you must
perform the following two steps to complete the INITIAL CONSOLE PROGRAMMING:
a) Enter "1.0" for PROD 2 CAL.
b) Re-enter "0" for PROD 2 CAL.
YOU HAVE NOW COMPLETED REQUIRED PROGRAMMING FOR THE CONSOLE
17) The flashing "CAL" should now extinguish. If not, repeat the programming procedures starting at
Step 9.
2. OTHER DISPLAY FEATURES
1) To display TOTAL AREA covered, momentarily depress . To "zero out" this total at any time,
enter a "0" in this key.

Table of Contents

Other manuals for Raven SCS 700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raven SCS 700 and is the answer not in the manual?

Raven SCS 700 Specifications

General IconGeneral
BrandRaven
ModelSCS 700
CategoryMusic Mixer
LanguageEnglish

Related product manuals