18
Progressive warming cement slab during 21 days period,
but limited to 20°C.
Working description:
To activate this option the user enters the installer menu
number 4 and selects the configuration (‘on’ or ‘off’) and
validate.
When the thermostat comes back to the normal mode, the
user sees instead of the temperature, the remaining number
of days of the progressive warming (total duration: 21 days).
During this time, the thermostat warming cycle is equal to
24 minutes (60 cycles per day).
The first day, the thermostat powers the
floor heating system during 1 minute on
each 24 min cycle (= 1h of warming the
first day).
The second day, the thermostat powers the
floor heating system during 2 minutes on
each 24 min cycle (= 2h of warming the
second day).
Before the last day, the thermostat powers
the floor heating system during 19 minute
on each 24 min cycle (= 19h of warming
the first day).
The last day, the thermostat powers the
floor heating system during 20 minute on
each 24 min cycle (= 20h of warming the
first day).
Function
remains active
for 21 day.
Function
remains active
for 1 days.