3) Requirements for output cable cooling system:
Rate of liquid flow: 1.7-2.0 L/min;
Pressure of liquid flow: < 0.6 MPa at the inflow;
Type of liquid exchange junction: SMC MS-5H-6:
Type of tube: outer diameter ϕ6; inner diameter ϕ4;
Direction of cooling liquid: unidirectional; connect the tube with the water-pipe strictly
according to direction shown on the layer of the tube;
Type of liquid: de-ionized water, condensed water, pure water;
PH value of liquid: 5.5 - 9;
Filter is needed for the cooling system, and the size of the solid residual practicals
should be within 100um;
Maximum temperature of liquid: 45
:
Minimum temperature of liquid: greater than the saturated dew-point 5
;
Additive to the liquid: satisfies the requirements of PH value and size of solid residual
practicals as above;
Radius of the bending of the armored pipe: off-work state (i.e. transportation and
reservation): minimum radius of bending 20 cm; in-work state: minimum radius of bending >=
30 cm;
Long-term vibration < 2 G; Impact action < 10 G.
4) Other requirements for chiller:
When starting the cooling system for the first time, check the entire water system and
the joint for water leakage. The external water pipe must be installed and connected according to
the inlet (IN) and outlet (OUT) by the laser. Otherwise, the laser may not work properly.
If you will not use the laser for a long time, water must be emptied from the product,
and then both the inlet and outlet must be blocked with the nuts we provide. Failure to do so may
lead to permanent equipment damage.