Wuhan Raycus Fiber Laser Technologies Co., Ltd
User Guide of Global Version 2000 W CW laser
Raycus User Guide | Common Alarms and solutions
Table 12 Error instructions and possible solutions
Error instructions and possible solutions
Instruction:
Internal clock abnormal.
Solutions:
When this alarm occurs, please contact Raycus directly.
Instruction:
This alarm occurs when the light exit button on the front panel
of the laser has been pressed before powering on.
Solutions:
When this alarm occurs, please power off the laser and make
the light enable button pop up, and then power on the laser
again to cancel the alarm. If the alarm continues to occur,
please contact Raycus.
Instruction:
Occurs when the laser Interlock is disconnected.
Solutions:
Short the Interlock pins. If this error continues to occur, please
contact Raycus.
Instruction:
Internal constant current driver is error.
Solutions:
Restart the Device. If this error continues to occur, please
contact Raycus.
Instruction:
The laser will get this alarm when it can not detect any laser
light signal. Laser out alarm occurs only when the laser is
emitting light
Solutions:
Restart the Device. If this error continues to occur, please
contact Raycus.
Instruction:
The alarm is generated when the emission of the laser cannot
reach the set value. Power alarm occurs only when the laser is
emitting light.
Solutions:
Restart the Device. If this error continues to occur, please
contact Raycus.
Instruction:
AC/ DC1 Alarm. Laser power supply out of work or sudden
power disconnect of the power supply system may cause the
alarm.