Power supply: 10 to 16V
Power consumption: 60mA (without illumination)
100mA (illuminated)
Transmitted power (RMS): 50W
Operating frequency: 200kHz
Temperature range: 0 to 70 deg° C
Shallow alarm: 1 to 10m (0.1 increments)
3 to 33ft (1ft increments)
Deep alarm: 3 to 120m (1m increments)
10 to 400ft (10ft increments)
Offset: –4 to +4m (0.1 increments)
–9.9 to +9.9ft (0.1 increments)
Minimum depth function: Reset on power-up
Units: Software programmable selection
in metres (m) or feet (ft) – stored
in EPROM
Calibration lock/unlock: Software programmable
Repeater capability: Software programmable