Fishndercolorthreshold
Thecolorthresholdsettingdeterminestherangeofcolors
usedonscreen.Theeffectofthisistosetacolorthreshold
belowwhichtargetsarenotshown.Forexamplealowsetting
wouldresultinonlythestrongest(orangeandred)targetsbeing
displayed.
Adjustingtheshndercolorthreshold
Fromtheshnderapplication:
1.SelectMenu.
2.SelectSensitivitySettings.
3.SelectColorThreshold.
Selectingcolorthresholddisplaysthenumericadjustcontrol.
4.Adjustthecolorthresholdtotherequiredsetting.
5.SelectOktoconrmsettingandclosethenumericadjust
control.
Fishnderpower
Thepowersettingcontrolsthepowerlevelofthetransducer.
Poweroptions:
Auto.Thisisthedefaultsetting.Whenitisselectedthe
sonarmoduleautomaticallydeterminestherequiredpower
settingbasedonthecurrentdepth,speed,and(bottom)signal
strength..
Manual.Ifyouwishtomanuallyadjustthepowertosuit
currentconditions,youcanadjustthepowerlevelbetween
0%and100%,in10%increments.Lowerpowerlevelsare
normallyusedindepthrangeslessthan8ft.(2.4m)and
higherpowerlevelsaretypicallyselectedfordepthsgreater
than12ft.(3.7m).
Settingthefrequencyforpowermode
WhenconnectedtoaRaymarineCHIRPsonarmodule,the
powermodeforfrequency1andfrequency2canbechanged
independentlyorbothatthesametime.Ifconnectedtoa
non-CHIRPsonarmoduleadjustmentswillbemadetoboth
frequenciessimultaneously.
1.SelectMenu.
2.SelectSensitivitySettings.
3.SelectPowerMode.
4.SelectAdjust.
5.SelectFrequency1,Frequency2orBoth.
Adjustingtheshnderpower
Fromtheshnderapplication:
1.SelectMenu.
2.SelectSensitivitysettings.
3.SelectPowerMode.
Thepowermodesliderbarcontrolisdisplayed.
4.Adjustthesliderbartotherequiredsetting,or
5.SelectAutotoplacepowermodeintoautomatic.
Thenewvaluesremainsetevenwhenyouswitchoffthedisplay
andareappliedtoallshnderwindows.
17.15Fishnderpresentationoptions
ThePresentationmenugivesyouaccesstofeaturesand
functionswhichprovideadditionalon-screenfunctionality.
Presentationoptionsinclude:
MenuItemDescriptionOptions
TargetDepthID
Controlswhetherthe
depthofidentied
targetsaredisplayed.
Theleveloftargets
displayedisdirectly
linkedtothelevelof
FishAlarmsensitivity.
On
Off
DepthLines
Controlswhether
horizontallines
indicatingdepthare
displayed.
On
Off
WhiteLines
WhensettoOn,this
optiondisplaysawhite
linealongthecontour
oftheseabed.This
helpstodistinguish
objectsclosetothe
bottom.
On
Off
BottomFill
WhensettoOn,this
optiondisplaysasolid
colorllfortheseabed.
On
Off
ColorPalette
Variouscolorpalettes
areavailabletosuit
differentconditions
andyourpersonal
preference.
ClassicBlue
ClassicBlack
ClassicWhite
Sunburst
Greyscale
InverseGreyscale
Copper
NightVision
PingRateHyperPingisa
shndersettingfor
usewhentravellingat
highspeedinshallow
waters.Whensetto
Hyperthedisplaywill
provideanaccurate,
undistortedimageof
thebottomatspeeds
ofupto40kt.
Note:Theping
rateoptionisnot
availablewhen
connectedtoa
RaymarineCHIRP
sonarmodule.
Normal
Hyper
ScrollSpeedSpecifytheshnder
scrollspeed.
10%100%
GaincontrolsControlswhetheror
nottheon-screenGain
andTVGcontrolsare
shownornot
Note:Gain
controlssetting
isonlyavailable
ontouchscreen
multifunction
displays.
Show(default)
Hide
DataOverlaySet-up
Allowsyoutosetup
anddisplay/hideup
to2datacellsinthe
DataCell1
On
Fishnderapplication
197