EasyManua.ls Logo

Raymarine c97 - Power Connection - New C Series and New E Series

Raymarine c97
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.4PowerconnectionNewcSeries
andNeweSeries
D12 25 0-1
1
2
4
5
7
3
8
6
9
1.Multifunctiondisplayconnections.
2.Poweranddatacable.
3.Connectionto12/24Vpowersupply(e7/e7Dis12Vonly).
4.Redcable(positive).
5.Fuse.
6.Blackcable(negative).
7.Videoinputcable.
8.NMEA0183datacables.
9.Shield(drain)wire(thinblackwire;mustbeconnectedto
RFgroundpoint).
Powerdistribution
Raymarinerecommendsthatallpowerconnectionsaremade
viaadistributionpanel.
Allequipmentmustbepoweredfromabreakerorswitch,with
appropriatecircuitprotection.
Allequipmentshouldbewiredtoindividualbreakersif
possible.
Warning:Productgrounding
Beforeapplyingpowertothisproduct,ensureithas
beencorrectlygrounded,inaccordancewiththe
instructionsinthisguide.
GroundingDedicateddrainwire
Thepowercablesuppliedwiththisproductincludesadedicated
shield(drain)wireforconnectiontoavessel'sRFgroundpoint.
ItisimportantthataneffectiveRFgroundisconnectedtothe
system.Asinglegroundpointshouldbeusedforallequipment.
Theunitcanbegroundedbyconnectingtheshield(drain)wire
ofthepowercabletothevessel'sRFgroundpoint.Onvessels
withoutanRFgroundsystemtheshield(drain)wireshouldbe
connecteddirectlytothenegativebatteryterminal.
Thedcpowersystemshouldbeeither:
Negativegrounded,withthenegativebatteryterminal
connectedtothevessel'sground.
Floating,withneitherbatteryterminalconnectedtothe
vessel'sground
Warning:Positivegroundsystems
Donotconnectthisunittoasystemwhichhas
positivegrounding.
Powercable
Thedisplayissuppliedwithacombinedpoweranddatamulti
cable,thiscanbeextendedifrequired.
Powercablesavailable
CablePartnumberNotes
1.5m(4.9ft)Straight
poweranddatacable
R62379
1.5m(4.9ft)Right
angledpoweranddata
cable
R70029
Cableextension
Thefollowingrestrictionsapplytoanyextensiontothepower
cable:
Cablemustbeofasuitablegaugeforthecircuitload.
Eachunitshouldhaveitsowndedicatedpowercablewired
backtothedistributionpanel.
Totallength(max)SupplyvoltageCablegauge(AWG)
12V18
0–5m(0–16.4ft)
24V20
12V14
5–10m(16.4–32.8ft)
24V18
12V12
10–15m(32.8–49.2ft)
24V16
12V12
15–20m(49.2–65.5ft)
24V14
Note:Thesedistancesarefora2wirepowercablerunfromthe
batterytothedisplay(approximatelythedistancefromthebatterytothe
display).Tocalculatetheroundtriplength,doublethegurestatedhere.
Breakers,fusesandcircuitprotection
Thepowercableincludesanin-linefuse.Itisrecommendedthat
youtanadditionalthermalbreakerorfuseatthedistribution
panel.
FuseratingThermalbreakerrating
7Ain-linefusettedwithinpower
cable.
5A(ifonlyconnectingonedevice)
Note:Thesuitablefuseratingforthethermalbreakeris
dependentonthenumberofdevicesyouareconnecting.Ifin
doubtconsultanauthorisedRaymarinedealer.