EasyManua.ls Logo

Raymarine c97 - Power Connection - New a Series

Raymarine c97
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.3PowerconnectionNewaSeries
0
0
0
0
0
0
0
0
0
0
00
0
0
0
0
0
00
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
6
2
4
5
3
D12 58 1-1
1.Multifunctiondisplayrearpanelconnections.
2.Powercable.
3.Connectionto12Vpowersupply
4.Redcable(positive).
5.Shield(drain)wire(thinblackwire;mustbeconnectedto
RFgroundpoint).
6.Blackcable(negative).
Powerdistribution
Raymarinerecommendsthatallpowerconnectionsaremade
viaadistributionpanel.
Allequipmentmustbepoweredfromabreakerorswitch,with
appropriatecircuitprotection.
Allequipmentshouldbewiredtoindividualbreakersif
possible.
Warning:Productgrounding
Beforeapplyingpowertothisproduct,ensureithas
beencorrectlygrounded,inaccordancewiththe
instructionsinthisguide.
GroundingDedicateddrainwire
Thepowercablesuppliedwiththisproductincludesadedicated
shield(drain)wireforconnectiontoavessel'sRFgroundpoint.
ItisimportantthataneffectiveRFgroundisconnectedtothe
system.Asinglegroundpointshouldbeusedforallequipment.
Theunitcanbegroundedbyconnectingtheshield(drain)wire
ofthepowercabletothevessel'sRFgroundpoint.Onvessels
withoutanRFgroundsystemtheshield(drain)wireshouldbe
connecteddirectlytothenegativebatteryterminal.
Thedcpowersystemshouldbeeither:
Negativegrounded,withthenegativebatteryterminal
connectedtothevessel'sground.
Floating,withneitherbatteryterminalconnectedtothe
vessel'sground
Warning:Positivegroundsystems
Donotconnectthisunittoasystemwhichhas
positivegrounding.
Powercable
Thedisplayissuppliedwithapowercable,thiscanbeextended
ifrequired.
Powercablesavailable
Forushmountinstallationsarightangledpowercable(not
supplied)isavailable.
CablePartnumberNotes
Rightangledpower
cable
A80221
Cableextension
Thefollowingrestrictionsapplytoanyextensiontothepower
cable:
Cablemustbeofasuitablegaugeforthecircuitload.
Eachunitshouldhaveitsowndedicatedpowercablewired
backtothedistributionpanel.
Totallength(max)SupplyvoltageCablegauge(AWG)
0–5m(0–16.4ft)
12V18
5–10m(16.4–32.8ft)
12V14
10–15m(32.8–49.2ft)
12V12
15–20m(49.2–65.5ft)
12V12
Note:Thesedistancesarefora2wirepowercablerunfromthe
batterytothedisplay(approximatelythedistancefromthebatterytothe
display).Tocalculatetheroundtriplength,doublethegurestatedhere.
Breakers,fusesandcircuitprotection
Itisrecommendedthatyoutathermalbreakerorfuseatthe
distributionpanel.
Thermalbreakerrating
5A(ifonlyconnectingonedevice)
Note:Thesuitablefuseratingforthethermalbreakeris
dependentonthenumberofdevicesyouareconnecting.Ifin
doubtconsultanauthorizedRaymarinedealer.
40NewaSeries/NewcSeries/NeweSeries

Table of Contents

Other manuals for Raymarine c97

Related product manuals