EasyManua.ls Logo

Raymarine E70096 - SeaTalkng System Loading; Power Distribution - SeaTalkng

Raymarine E70096
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smallsystems
Ifthebackbonelengthis60m(197ft)orless,thepowerconnectionpointmaybeconnectedat
anypointinthebackbone
.
In-linefuseandthermalbreakerratings
TheSeaTalkng®network’spowersupplyrequiresanin-linefuseorthermalbreakertobefitted.
In-linefuserating:5A
Thermalbreakerrating:3A(refertonotebelow)
Note:
Thesuitablefuseratingforthethermalbreak erisdependenton:1)Howmanydevicesyouhave
connectedtoyourSea Talkng®network;and2)Howmanydevicesaresharingthesamethermal
breakerthatyourSeaTalkng®networkisconnectedto.
Sea Talkng®systemloading
Themaximumloading/LENforaSea Talkng®systemdependsonthelengthofthebackbone.
Unbalancedsystemloading:
BackboneL ength:0m(0ft)to20m(66ft)MaximumLEN:40
BackboneLength:>20m(66ft)to40m(131ft)MaximumLEN:20
BackboneLength:>40m(131ft)to60m(197ft)MaximumLEN:14
Balancedsystemloading:
BackboneL ength:0m(0ft)to60m(197ft)MaximumLEN:100
BackboneLength:>60m(197ft)to80m(262ft)MaximumLEN:84
BackboneLength:>80m(262ft)to100m(328ft)MaximumLEN:60
BackboneLength:>100m(328ft)to120m(394ft)MaximumLEN:50
BackboneLength:>120m(394ft)to160m(525ft)MaximumLEN:40
BackboneLength:>160m(525ft)to200m(656ft)MaximumLEN:32
9.6PowerdistributionSeaTalkng®
Recommendationsandbestpractice.
OnlyuseapprovedSea Talkng®powercables.DoNOTuseapowercabledesignedfor,or
suppliedwith,adifferentproduct.
Seebelowformoreinformationonimplementationforsomecommonpowerdistributionscenarios.
Important:
Whenplanningandwiring,tak eintoconsiderationotherproductsinyoursystem,someofwhich
(e.g.sonarmodules)mayplacelargepowerdemandpeaksonthevessel’selectricalsystem,
whichmayimpactthevoltageavailabletootherproductsduringthepeaks.
Theinformationprovidedbelowisforguidanceonly,tohelpprotectyourproduct.Itcovers
commonvesselpowerarrangements,butdoesNOTcovereveryscenario.Ifyouareunsure
howtoprovidethecorrectlevelofprotection,pleaseconsultanauthorizedRaymarinedealeror
asuitablyqualifiedprofessionalmarineelectrician.
Sea Talkng®powercable(A06049)
WhenpoweringtheSeaTalkng®bus(backboneor5–wayconnector)fromabatteryordistribution
panel,theA06049powercablemustbeused.
All3coresofthecablemustbeconnectedcorrectly:
EV -1connections61

Table of Contents

Related product manuals