GroundingDedicateddrainwirerequired
Thisproductincludesadedicateddrainconductor(screen)forconnectiontoavessel'
sRFground
point.
ItisimportantthataneffectiveRFgroundisconnectedtotheunit.Theunitcanbegroundedby
connectingthedrainconductor(screen)tothevessel'sRFgroundpoint.OnvesselswithoutanRF
groundsystemthedrainconductor(screen)shouldbeconnecteddirectlytothenegativebattery
terminal.
Thedcpowersystemshouldbeeither:
Negativegrounded,withthenegativebatteryterminalconnectedtothevessel'sground;or
Floating,withneitherbatteryterminalconnectedtothevessel'sground.
Ifseveralitemsrequiregrounding,theymayfirstbeconnectedtoasinglelocalpoint(e.g.withina
switchpanel),withthispointconnectedviaasingle,appropriately-ratedconductor,tothevessel’s
commonRFgroundpoint.
Implementation
Thepreferredminimumrequirementforthepathtogroundisviaaflattinnedcopperbraid,with
a30Arating(1/4inch)orgreater.Ifthisisnotpossible,anequivalentstrandedwireconductor
maybeused,ratedasfollows:
forrunsof<1m(3ft),use6mm
2
(#10AWG)orgreater.
forrunsof>1m(3ft),use8mm
2
(#8AWG)orgreater.
Inanygroundingsystem,alwayskeepthelengthofconnectingbraidorwiresasshortaspossible.
References
ISO10133/13297
BMEAcodeofpractice
NMEA0400
PowerdistributionACU
Recommendationsandbestpractice.
TheproductisNOTsuppliedwithapowercable.PleaserefertothePoweranddrivecables
sectionforpowercablerequirements.
Refertothe
Powerconnection
sectionformoreinformationonhowtoidentifythewiresinyour
product’spowercable,andwheretoconnectthem.
Seebelowformoreinformationonimplementationforsomecommonpowerdistributionscenarios.
Important:
Whenplanningandwiring,tak eintoconsiderationotherproductsinyoursystem,someofwhich
(e.g.sonarmodules)mayplacelargepowerdemandpeaksonthevessel’selectricalsystem.
Note:
Theinformationprovidedbelowisforguidanceonly ,tohelpprotectyourproduct.Itcovers
commonvesselpowerarrangements,butdoesNOTcovereveryscenario.Ifyouareunsurehow
toprovidethecorrectlevelofprotection,pleaseconsultanauthorizedRaymarinedealerora
suitablyqualifiedprofessionalmarineelectrician.
Implementationdirectconnectiontobattery
Theunitmaybeconnecteddirectlytothevessel' sbattery,viaasuitablyratedfuseorbreaker.
TheunitalsorequiresaseparateRFGround(drain)connection,refertothefollowingsection:
GroundingDedicateddrainwirerequired
.
YouMUSTfitasuitably-ratedfuseorbreakerbetweentheredwireandthebattery’spositive
terminal.ThisisrequiredinadditiontotheinternalfusefittedtotheACU.
Refertothetablebelowforsuitablefuseratings.
A CU-200,ACU-300,ACU-400connections
89