Implementationconnectiontodistributionpanel
Alternatively ,theunit’spowerconnectionmaybeconnectedtoasuitablebreakerorswitchonthe
vessel'spowerdistributionpanel,orfactory-fittedpowerdistributionpoint.
Thedistributionpointshouldbefedfromthevessel’sprimarypowersourceby8AWG(8.36mm
2
)
cable.
TheunitalsorequiresaseparateRFGround(drain)connection,refertothefollowingsection:
GroundingDedicateddrainwirerequired
.
Ideally,allequipmentshouldbewiredtoindividualsuitably-ratedthermalbreakersorfuses,with
appropriatecircuitprotection.Wherethisisnotpossibleandmorethan1itemofequipmentshares
abreaker,useindividualin-linefusesforeachpowercircuittoprovidethenecessaryprotection.
Inallcases,observetherecommendedbreakerratingsprovidedinthefollowingtable.
Thermalbreakerratingsconnectionviadistributionpanel
A CUThermalbreakerrating
A CU-10010A
A CU-150
15A
A CU-20020A
A CU-300
15A
A CU-40040A
Important:
Beawarethatthesuitablefuseratingforthethermalbreak erorfuseisdependentonthenumber
ofdevicesyouareconnecting.
Grounding
Ensurethatyouobservethededicatedgroundingadviceprovided.
Moreinformation
Itisrecommendedthatbestpracticeisobservedinallvesselelectricalinstallations,asdetailed
inthefollowingstandards:
BMEACodeofPracticeforElectricalandElectronicInstallationsinBoats
NMEA0400InstallationS
tandard
ABYCE-11AC&DCElectricalSystemsonBoats
ABYCA-31BatterychargersandInverters
ABYCTE-4LightningProtection
A CU-200,ACU-300,ACU-400connections