EasyManua.ls Logo

Raymarine E70293 - Testing and Adjusting the Transducer

Raymarine E70293
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.4Testingandadjustingthe
transducer
Oncetheinitialmountingprocedureshavebeen
carriedout,thetransducermustbetestedpriorto
nishingthemounting.
Thetestingshouldbecarriedoutwithyourvessel
inthewater,withadepthgreaterthan0.7m(2.3
ft)butlessthanthemaximumdepthrangeofthe
transducer.
Important:TheSonarchannelwillbeableto
maintainreadingsathighervesselspeedsandat
greaterdepthsthantheDownVision
application.
1.PressandholdthePowerbuttontopowerthe
uniton.
2.CompletetheStart-upwizardandtutorial.
3.Opentherelevantapplication.
Thebottomshouldbevisibleonscreenanda
depthreadingdisplayed.
4.Startmovingyourvesselatalowspeed,ensuring
youhaveadepthreadingandaclearimageis
displayed.
5.Graduallyincreasethevesselspeedwhilst
checkingthedisplay,iftheimagebecomespoor
orthebottomismissingatlowerspeedsthenthe
transducerneedstobeadjusted.
6.Angleandheightadjustmentsshouldbemadein
smallincrementsandre-testedeachtimeuntil
youobtainoptimumperformance.
D13195-1
D13196-1
7.Loosentheratchetarmbolttoadjustthe
transducerangle.
8.Loosenthe2mountingbracketscrewstoadjust
thetransducerheight.
9.Re-tightentheratchetarmboltandmounting
screwsbeforere-testing.
Note:
Itmaynotalwaysbepossibletoobtaindepth
readingsathigherspeedsduetoairbubbles
passingunderthetransducer.
Itmaybenecessarytomakeseveral
adjustmentstothetransducerbeforeobtaining
optimumperformance.
Ifthetransducerrequiresrepositioningensure
alloldholesarelledwithmarinegradesealant.
Removingthetransducer
Thetransducercanbereleasedfromthebracketby
insertingasmallmetalrodsuchasapaperclipinto
thetransducerreleaseholelocatedasshown.
D13189-1
1.Insertthemetalrodintothetransducerrelease
hole.
2.Slidethetransduceroffofthebracket.
32
Dragony–4/Dragony–5/Dragony–7/Wi–Fish

Table of Contents