8.
1Technicalspecification
Physicalspecification
Overalldimensions:
L
ength:224.99mm(8.86in)
Height:112.69mm(4.44in)
Width:76.00mm(2.99in)
Cablelength:
HV-100:6m(19
.69ft)fittedcable
W eight(unboxed):1.05kg(2.31lb)
Environmentalspecification
Operatingtemperature
–2ºC(28.4ºF)to+55ºC(131ºF)
S toragetemperature
–20ºC(23ºF)to+70ºC(158ºF)
W aterproofrating
IPx6(surfacesexteriortohull,only)
IPx7
IPx8
Hyper Visiontechnicalspecification
ThefollowingspecificationonlyappliestoHyperVision™products.
Frequencies
1.2MHzCHIRP
350kHzCHIRP
200kHzCHIRP
ChannelsConicalCHIRPsonar
R ealVision3D(Hyper)
RealVision3D(Standard)
SideVision(Hyper)
SideVision(Standard)
DownVision(Hyper)
DownVision(Standard)
200kHzrange
ConicalCHIRPsonar=0 .6M(2ft)to274m(900ft)
350kHzrange
R ealVision3D=0.6M(2ft)to91m(300ft)
SideVision=0.6M(2ft)to91m(300ft)eachside
DownVision=0.6M(2ft)to183m(600ft)
1.2MHzrange
R ealVision3D=0.6M(2ft)to38m(125ft)
SideVision=0.6M(2ft)to38m(125ft)eachside
DownVision=0.6M(2ft)to38m(125ft)
Conformancespecification
ConformanceEN60945:2002
IEC28846:1993
EMCDirective2014/30/EU
A
ustraliaandNewZealand:C-Tick,ComplianceLevel2