7.2Intermediatecalibration
Intermediatecalibrationallowsyouto:
•Checkinstrumentsoftwareversion
•*Checktheinstrumentstatus(eithermasteror
repeater)
Note:*Notavailableoni60CHWind.
10
15
20
25
30
35
40
45
50
55
60
5
4
+
D12492-2
CAL
CAL
Display
Display
True /App
Checkingthesoftwareversionand
instrumentstatus
Youcanchecktheinstrumentdisplay’ssoftware
versionandstatusbyfollowingthestepsbelow.
Note:Thei60CHWindinstrumentisarepeater
display.Youcannotcheckorchangethe
instrumentstatusofani60CHWinddisplay
Fromthesoftwareversionpage:
10
15
20
25
30
35
40
45
50
55
60
5
4
+
D12492-2
CAL
CAL
Display
Display
True /App
Duringnormaloperation:
1.PressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately4
seconds,untiltheSoftwareVersionpageis
displayed.
2.PresstheDisplaybuttontoshowtheInstrument
Statuspage.
Theinstrumentstatusisdisplayed(r0=master
andr1=repeater).
Note:TheSoftwareVersionandInstrumentStatus
pagesaretemporarypagesandwilltime-out
automaticallyafter8secondsofinactivity.
7.3Dealercalibration
Thedealercalibrationproceduresinclude:
•UsercalibrationmenuaccessOn(default)andOff.
•DisplayResponseforwindanglereadings—
Dictatestherateatwhichtheinstrumentdisplay
respondstochangesinwindangledata.
•DisplayResponseforwindspeedreadings—
Dictatestherateatwhichtheinstrumentdisplay
respondstochangesinwindspeeddata.
•DisplayResponseforVMGreadings—Dictates
therateatwhichtheinstrumentdisplayresponds
tochangesinVMGdata.
•*BoatshowmodeOnandOff(default)(Boat
showmodeisonlyavailableondisplayssetas
repeaters).
•Resettofactorydefaults.
Note:Notavailableonthei60CHwindinstrument.
AccessingtheDealerCalibrationMenu-i60
Duringnormaloperation:
1.PressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately14
seconds,untiltheDealerCalibrationpageis
displayed.
10
15
20
25
30
35
40
45
50
55
60
5
14
+
D12493-2
CAL
Display
True /App
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
SettingaccesstotheUserCalibrationMenu
-i60
FromtheDealerCalibrationpage:
1.PresstheVMGandTackbuttonsatthesame
timetodisplaytheUserCalibrationMenu
Accesspage.
2.UsetheVMGorTackbuttonstoswitchaccessto
theUserCalibrationMenuOnandOff.
•UC1(default)—UserCalibrationmenu
enabled
•UC0—UserCalibrationmenudisabled
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDisplayandTrue/App
buttonsatthesametimeforapproximately2
seconds.
SettingtheresponsedelayforWindAngle
readings
FromtheUserCalibrationMenuAccesspage:
Calibration39