EasyManua.ls Logo

Raymarine i50 Depth User Manual

Raymarine i50 Depth
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
i50 Depth
i50 Speed
i50 T rida t a
Installation and operation
instructions
English
Date: 06-2014
Document number: 81341-2-EN
© 2014 Raymarine UK Limited
i50

Table of Contents

Questions and Answers:

Raymarine i50 Depth Specifications

General IconGeneral
BrandRaymarine
Modeli50 Depth
CategoryMarine Equipment
LanguageEnglish

Summary

Important Information

Certified Installation

Details for obtaining enhanced warranty benefits through certified installation.

Water Ingress

Disclaimer regarding water intrusion and potential equipment failure from high-pressure washing.

Disclaimer

Information on product warranty, compatibility, and liability for damages or injuries.

EMC Installation Guidelines

Guidelines for proper installation to ensure optimal Electromagnetic Compatibility performance.

Suppression Ferrites

Importance and correct usage of suppression ferrites for EMC performance.

Connections to Other Equipment

Requirement for suppression ferrites on non-Raymarine cables.

Declaration of Conformity

Statement of compliance with essential requirements of EMC directive 2004/108/EC.

Product Disposal

Instructions for disposing of the product in accordance with the WEEE Directive.

Warranty Registration

Guidance on registering product ownership online for full warranty benefits.

IMO and SOLAS

Intended use for leisure boats and workboats, not IMO/SOLAS carriage regulations.

Technical Accuracy

Information on document accuracy, potential inaccuracies, and product improvement changes.

Handbook Information

Document Information

Details about the document, its purpose, and applicable Raymarine products.

Parts Supplied

List and illustrations of components included in the product package.

i50 Product Overview

General features and capabilities of the i50 instrument display range.

Planning the Installation

Installation Checklist

A step-by-step guide for planning and executing the installation process.

Compatible Transducers for i50 Displays

List of depth and speed transducers compatible with i50 instrument displays.

Typical System Configurations

Diagrams illustrating basic and extended SeaTalkng system configurations.

System Protocols Explained

Explanation of SeaTalkng, NMEA 2000, and SeaTalk protocols for system connectivity.

Tools Required for Installation

List of essential tools needed for the installation of the instrument.

Selecting a Display Location

Factors to consider when choosing a suitable mounting location for the display unit.

Product Dimensions

Detailed measurements and specifications of the i50 instrument unit.

Selecting a Transducer Location

Guidelines for choosing optimal mounting positions for speed and depth transducers.

Cables and Connections

General Cabling Guidance

Best practices for cable types, routing, strain relief, and shielding.

Power Connection

Instructions for connecting the 12V DC power supply to the SeaTalkng network.

SeaTalkng Connections

Procedure for connecting SeaTalkng cables to the unit's rear connectors.

Transducer Connections

Details on connecting depth and speed transducers using spade connectors.

iTC-5 Connection

Connecting transducers via the iTC-5 converter for data distribution.

SeaTalk Connection

Connecting to an existing SeaTalk system using a SeaTalk to SeaTalkng adaptor.

NMEA2000 Connection

Methods for connecting the unit to SeaTalkng or existing NMEA2000 backbones.

Mounting the i50 Instrument

Mounting Procedure

Instructions for surface mounting the i50 instrument display unit.

Front Bezel Removal

Procedure for safely removing and refitting the front bezel of the unit.

i50 Depth Instrument

i50 Depth Operation

Overview of the i50 Depth instrument's functions and data display capabilities.

i50 Depth Controls

Description of the buttons and their functions for operating the i50 Depth unit.

Powering the Unit On and Off

Procedures for powering the unit on and off, including countdown timers.

Data Master Configuration

Setting the instrument status as Master or Repeater for system data distribution.

Calibration Procedures

Overview of user, intermediate, and dealer calibration procedures for optimal performance.

User Calibration - i50 Depth

Steps for setting depth units and applying depth offsets in user calibration.

Intermediate Calibration - i50 Depth

Checking software version and setting instrument status (Master/Repeater).

Dealer Calibration - i50 Depth

Advanced settings including user access, response delay, and factory reset.

Using the Depth Pages

Navigating through current depth, minimum, and maximum depth display pages.

Viewing the Depth Offset

How to view the applied waterline or keel offset value for depth readings.

Alarms Configuration

Setting and managing shallow/deep depth and anchor alarms for the i50 Depth unit.

Illumination Settings

Adjusting backlight and contrast levels, and configuring group illumination.

i50 Speed Instrument

i50 Speed Operation

Overview of the i50 Speed instrument's functions and data display capabilities.

i50 Speed Controls

Description of the buttons and their functions for operating the i50 Speed unit.

Powering the Unit On and Off

Procedures for powering the unit on and off, including countdown timers.

Data Master Configuration

Setting the instrument status as Master or Repeater for system data distribution.

Calibration Procedures

Overview of user, intermediate, and dealer calibration procedures for optimal performance.

User Calibration - i50 Speed

Settings for speed units, resolution, log units, temp units, speed offset, timer buzzer.

Intermediate Calibration - i50 Speed

Checking software version and performing speed run calibration for accurate readings.

Dealer Calibration - i50 Speed

Advanced settings: user access, response delay, boat show mode, and factory reset.

Navigating the Speed Pages

Navigating through current, maximum, average speed, VMG, and SOG pages.

Using Log, Trip, and Temperature Pages

Accessing and viewing log, trip, and water temperature data.

Using the Timers

Operating race start timers and stopwatch, including buzzer settings.

Illumination Settings

Adjusting backlight and contrast levels, and configuring group illumination.

i50 Tridata Instrument

i50 Tridata Operation

Overview of the i50 Tridata instrument's functions and data display capabilities.

i50 Tridata Controls

Description of buttons for operating the i50 Tridata unit and navigating its display.

Powering the Unit On and Off

Procedures for powering the unit on and off, including countdown timers.

Data Master Configuration

Setting instrument status to Master or Repeater for data distribution.

Calibration Procedures

Overview of user, intermediate, and dealer calibration procedures for optimal performance.

User Calibration - i50 Tridata

Settings for depth, speed, log units, temp units, speed offset, and timer buzzer.

Intermediate Calibration - i50 Tridata

Checking software version and performing speed run calibration for accurate readings.

Dealer Calibration - i50 Tridata

Settings for user access, speed/depth response, SOG source, boat show mode, reset.

Using Tridata Depth Pages

Navigating depth pages: current, shallow/deep depth and anchor alarms.

Using Tridata Speed Pages

Navigating speed pages: current, max, average speed, VMG.

Using Tridata Trip, Log, Temp, and Timer Pages

Accessing trip, log, water temperature, and timer data displays.

Using the Timers

Operating race start timers and stopwatch, including buzzer settings.

Alarms Configuration

Setting and managing shallow/deep depth and anchor alarms for the i50 Tridata unit.

Illumination Settings

Adjusting backlight and contrast levels, and configuring group illumination.

Maintaining Your Display

Service and Maintenance

Information on product servicing, repairs, and authorized dealer services.

Condensation

Explanation of condensation on the unit's window and how it clears.

Routine Equipment Checks

Recommendations for regular checks to ensure reliable equipment operation.

Cleaning Best Practices

Best practices for cleaning the product, avoiding abrasive materials.

Cleaning the Display Case

Procedure for cleaning the sealed display unit case.

Cleaning the Display Screen

Procedure for cleaning the screen to maintain water repellency and prevent glare.

Troubleshooting Guide

Troubleshooting Introduction

Introduction to troubleshooting common marine electronics installation problems.

Instrument Troubleshooting

Diagnosing and resolving faults related to displays, data transfer, and transducer issues.

Power Up Troubleshooting

Solutions for problems encountered when the system or parts of it do not start up.

Miscellaneous Troubleshooting

Addressing erratic display behavior, resets, system crashes, and software mismatches.

Technical Support

Raymarine Customer Support

Information on contacting Raymarine for customer support via web, phone, and email.

Checking Software Version

Steps to identify the software version of the i50 instrument display.

Technical Specifications

i50 Series Technical Specifications

Detailed specifications including voltage, power, current, environmental, and connections.

Spares and Accessories

Available Spares

List of available spare parts for i50 instrument displays.

SeaTalkng Cables and Accessories

Details on SeaTalkng cables, connectors, and accessory kits.

Converters

Information on available converters, including SeaTalk to SeaTalkng.

Appendix A: NMEA 2000 Sentences

Supported NMEA 2000 PGN Sentences

List of supported NMEA 2000 Parameter Group Number (PGN) sentences.

Related product manuals