6.8Dealercalibration—i50Depth
DealerCalibrationenablesyoutoset:
•UsercalibrationmenuaccessOn(default)andOff.
•DisplayResponsefordepthreadings—Dictates
therateatwhichtheinstrumentdisplayresponds
tochangesindepthdata.
•BoatshowmodeOnandOff(default)(Boat
showmodeisonlyavailableondisplayssetas
repeaters).
•Resettofactorydefaults.
AccessingtheDealerCalibrationMenu
Duringnormaloperation:
1.PressandholdtheDepthandAlarmbuttons
atthesametimeforapproximately14seconds,
untiltheDealerCalibrationpageisdisplayed.
+
D12470-2
10
15
20
25
30
35
40
45
50
55
60
5
14
De pth
Alarm
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDepthandAlarmbuttons
atthesametimeforapproximately2seconds.
SettingaccesstotheUserCalibrationMenu
FromtheDealerCalibrationpage:
1.PresstheOffsetandResetbuttonsatthesame
timetodisplaytheUserCalibrationAccess
page.
D12471-2
+
Offs e t
Re s e t
2.UsetheOffsetandResetbuttonstoswitch
accesstotheUserCalibrationMenu
On(default)andOff.
SelectingOffdisablesaccesstotheUser
CalibrationMenu.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDepthandAlarmbuttons
atthesametimeforapproximately2seconds.
Settingtheresponsedelayfordepth
readings
FromtheUserCalibrationMenuAccesspage:
1.PresstheDepthbuttonuntiltheDepth
Responsepageisdisplayed(1pressfromthe
UserCalibrationMenuAccesspage).
2.UsetheOffsetandResetbuttonstoadjustthe
depthresponsetotherequiredlevel.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDepthandAlarmbuttons
atthesametimeforapproximately2seconds.
EnablinganddisablingBoatShowMode
FromtheUserCalibrationMenuAccesspage:
1.PresstheDepthbuttonuntiltheBoatShow
Modepageisdisplayed(2pressesfromUser
CalibrationMenuAccesspage).
2.UsetheOffsetandResetbuttonstoswitchboat
showmodeOnandOff(default).
SelectingOnwillputthedisplayintoboatshow
mode.
Note:Boatshowmodeisonlysuitablefor
demonstrationpurposesandshouldNOTbeused
whilstyourvesselisinuse.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDepthandAlarmbuttons
atthesametimeforapproximately2seconds.
Resettingthedisplaytofactorydefaults
FromtheUserCalibrationMenuAccesspage:
1.PresstheDepthbuttonuntiltheFactory
Defaultspageisdisplayed(3pressesfromUser
CalibrationMenuAccesspage).
2.Toresetthedisplaytofactorydefaultsettings:
i.UsetheOffsetorResetbuttonstochange
theresetoptiontoYes.
ii.PresstheDepthbuttontoresetyourdisplay
tofactorydefaultsettings.
3.Afteraresetitisrecommendedthatyoucheck
thedatamasterstatusofthedisplaytoensure
itissetcorrectly.Referto6.4Datamasterfor
details.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDepthandAlarmbuttons
atthesametimeforapproximately2seconds.
38i50