8.3Power
Poweringontheunit
Withpowertotheunitturnedonbuttheunitswitched
off:
1.PressandholdthePowerbuttonuntiltheunit
powersonanddataisdisplayed(approximately
2seconds).
Note:Whenpowertotheunitisturnedontheunit
willswitchonautomatically.
Poweringofftheunit
1.PressandholdthePowerbuttonuntilthepower
countdowntimerisdisplayedandreacheszero
(approximately6to8seconds).
8.4Datamaster
Whereasystemcontainsmorethanoneunit
capableofdisplayingadatatype,theunitphysically
connectedtothetransducermustbesetasthedata
masterandanyotherunitssetasarepeater.
Checkingi50Tridatasoftwareversionand
status
10
15
20
25
30
35
40
45
50
55
60
5
4
+
D12461-2
Depth
Spe e d
Depth
Duringnormaloperation:
1.PressandholdtheDepthandSpeedbuttonsat
thesametimeforapproximately4seconds,until
theSoftwareVersionpageisdisplayed.
2.PresstheDepthbuttontodisplaytheinstrument
status.
Master(transducerconnected)orRepeater(No
transducerconnected).
3.Tochangethedepthstatus:
i.PresstheTripandResetbuttonsatthesame
time.
Thestatuswillash.
ii.UsetheTriporResetbuttontoswitchthe
statusbetweenMasterorRepeater.
i.PresstheTripandResetbuttonsatthesame
timetoconrmthenewinstrumentstatus.
4.PresstheDepthbuttonagaintobeginspeedrun
calibration.
5.ToexittheIntermediatecalibrationsettingsat
anytime,pressandholdtheDepthandSpeed
buttonsatthesametimeforapproximately4
seconds: