D12468-2
Spe ed
Note:Thedisplayeddistanceshouldbeveryclose
totheactual(measured)distanceoftherun.
9.Ifyouaresatisedwiththeresultsoftherst
calibrationrun,presstheDepthandSpeed
buttonsatthesametimeforapproximately2
secondstosavethenewCalibrationFactor,exit
speedcalibrationandreturntonormaloperation.
10.Ifyouwanttocarryoutasecondrun,pressthe
Speedbutton.
11.Followsteps5to7aboveagaintocompletea
secondcalibrationrun.
12.AttheendofthereturnlegpresstheSpeed
button
Atthispoint:
ThetextENDalternatingwiththenew
CalibrationFactorisdisplayedatthetopofthe
page.
Thedisplayeddistancefreezes.
D12469-2
Spe ed
13.T oexittheSpeedRunCalibrationrunatanytime,
pressandholdtheDepthandSpeedbuttonsat
thesametimeforapproximately4seconds.
8.8Dealercalibrationi50Tridata
Thedealercalibrationproceduresinclude:
UsercalibrationmenuaccessOn(default)andOff.
DatasourceforspeedThedatasourcecanbe
settoSOGifthedisplayisconnectedtoanetwork
containingaGPSreceiver.
DisplayResponseforspeedreadingsDictates
therateatwhichtheinstrumentdisplayresponds
tochangesinspeeddata.
DisplayResponseforDepthreadingsDictates
therateatwhichtheinstrumentdisplayresponds
tochangesindepthdata.
BoatshowmodeOnandOff(default)(Boat
showmodeisonlyavailableondisplayssetas
repeaters).
Resettofactorydefaults.
AccessingtheDealerCalibrationMenu
FollowthestepsbelowtoaccesstheDealer
CalibrationMenu.
Duringnormaloperation:
1.PressandholdtheDepthandSpeedbuttons
atthesametimeforapproximately14seconds,
untiltheDealerCalibrationpageisdisplayed.
+
D12481-2
10
15
20
25
30
35
40
45
50
55
60
5
14
Depth
Spe ed
SettingaccesstotheUserCalibrationMenu
FromtheDealerCalibrationpage:
1.PresstheTripandResetbuttonsatthesame
timetodisplaytheUserCalibrationAccess
page.
D12482-2
+
Trip Re s e t
2.UsetheTripandResetbuttonstoswitchaccess
totheUserCalibrationMenuOn(default)and
Off.
SelectingOffdisablesaccesstotheUser
CalibrationMenu.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheDepthandSpeedbuttons
atthesametimeforapproximately2seconds.
SettingspeedtoSOG
YourinstrumentcanbesetuptouseSOGdata,if
availableasthesourceforspeeddatainsteadofa
speedtransducer.
WiththespeedsourcesettoSOGtheinstrument
displaywillignorespeedreadingsfromthe
connectedtransducerandonlydisplaySOG
readingsfromaconnectedGPSorGNSSreceiver.
FromtheUserCalibrationMenuAccesspage:
i50Tridata63