4.4Transducerconnections
i50Depthconnection
ItemCablecolorSignalname
1BlackPiezoceramic–
2BluePiezoceramic+
3
Screen0V(shield)
i50Speedconnection
ItemCablecolorSignalname
1BrownTemperature0V
2WhiteTemperature
(signal)
3
ScreenSpeed0V(shield)
4
GreenSpeed(signal)
5
Red
SpeedV+
i50Tridataconnection
ItemCablecolorSignalname
1
Black(Depth)
Piezoceramic–
2
Blue(Depth)
Piezoceramic+
3
Screen(Depth)0V(shield)
4
Brown(Speed)
Temperature0V
5
White(Speed)
Temperature
(signal)
6
Screen(Speed)Speed0V(shield)
7
Green(Speed)Speed(signal)
8
Red(Speed)SpeedV+
Makingtransducerconnections
Althoughthetransducercableisttedwithspade
connectorsfordirectconnectiontotherearofthe
unit,itmaybenecessarytoremovethesetofacilitate
installation,e.g.ifthecablehastoberoutedthrough
narrowapertures.1/8thspadeterminalswillbe
required(notsupplied),toreplacethoseremoved.
Whenttingthenewspadeconnectors,preparethe
cablesasdetailedbelow:
3 mm
6 mm
50 mm
1
2
D12 3 59-1
1.Preparethecableasshownin1above.
2.Foldbackthewirestrandsandinsertintothenew
spadeconnectorasshownin2above.
3.Ensurethewirestrandsdonotextendbeyond
therearofthespadeconnectorinsulation.
4.Crimptheconnectortothewire.