6.3Power
Poweringontheunit
Withpowertotheunitturnedonbuttheunitswitched
off:
1.PressandholdthePowerbuttonuntiltheunit
powersonanddataisdisplayed(approximately
2seconds).
Note:Whenpowertotheunitisturnedontheunit
willswitchonautomatically.
Poweringofftheunit
1.PressandholdthePowerbuttonuntilthepower
countdowntimerisdisplayedandreacheszero
(approximately6to8seconds).
6.4Datamaster
Whereasystemcontainsmorethanoneunit
capableofdisplayingadatatype,theunitphysically
connectedtothetransducermustbesetasthedata
masterandanyotherunitssetasarepeater.
Checkingi50Depthsoftwareversionand
status
10
15
20
25
30
35
40
45
50
55
60
5
4
+
D12451-2
Depth
Alarm
Depth
Duringnormaloperation:
1.PressandholdtheDepthandAlarmbuttonsat
thesametimeforapproximately4seconds,until
theSoftwareVersionpageisdisplayed.
2.PresstheDepthbuttontodisplaytheInstrument
Statuspage.
Master(transducerconnected)orRepeater(No
transducerconnected).
3.Tochangethestatus:
i.PresstheOffsetandResetbuttonsatthe
sametime.
Thestatuswillash.
ii.PresseithertheOffsetorResettochange
thestatusbetweenMasterorRepeater.
i.PresstheOffsetandResetbuttonsatthe
sametimetoconrmthestatus.
4.ToexittheIntermediatecalibrationsettingsat
anytime,pressandholdtheDepthandAlarm
buttonsatthesametimeforapproximately4
secondstoreturntonormaloperation.