EasyManua.ls Logo

Raymarine i50 Depth - Dealer Calibration - i50 Speed

Raymarine i50 Depth
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.8Dealercalibrationi50Speed
Thedealercalibrationproceduresinclude:
UsercalibrationmenuaccessOn(default)andOff.
DisplayResponseforspeedreadingsDictates
therateatwhichtheinstrumentdisplayresponds
tochangesinspeeddata.
DisplayResponseforVelocityMadeGood
(VMG)readingsDictatestherateatwhichthe
instrumentdisplayrespondstochangesinVMG
data.
BoatshowmodeOnandOff(default)(Boat
showmodeisonlyavailableondisplayssetas
repeaters).
Resettofactorydefaults.
AccessingtheDealerCalibrationMenu
Duringnormaloperation:
1.PressandholdtheSpeedandTripbuttonsatthe
sametimeforapproximately14seconds,until
theDealerCalibrationpageisdisplayed.
+
D12475-2
10
15
20
25
30
35
40
45
50
55
60
5
14
Spe ed
Trip
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheSpeedandTripbuttons
atthesametimeforapproximately2seconds.
SettingaccesstotheUserCalibrationMenu
FromtheDealerCalibrationpage:
1.PresstheTimerandResetbuttonsatthesame
timetodisplaytheUserCalibrationAccess
page.
D12476-2
+
Time r
Re s e t
2.UsetheTimerandResetbuttonstoswitch
accesstotheUserCalibrationMenu
On(default)andOff.
SelectingOffdisablesaccesstotheUser
CalibrationMenu.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheSpeedandTripbuttons
atthesametimeforapproximately2seconds.
Settingtheresponsedelayforspeed
readings
FromtheUserCalibrationMenuAccesspage:
1.PresstheSpeedbuttonuntiltheSpeed
Responsepageisdisplayed(1pressfromUser
CalibrationMenuAccesspage).
D12477-2
Spe ed
2.UsetheTimerandResetbuttonstoadjustthe
speedresponsetotherequiredlevel.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheSpeedandTripbuttons
atthesametimeforapproximately2seconds.
SettingtheresponsedelayforVMG(wind)
readings
FromtheUserCalibrationMenuAccesspage:
1.PresstheSpeedbuttonuntiltheVMGResponse
pageisdisplayed(2pressesfromUser
CalibrationMenuAccesspage).
D12478-2
Spe ed
2.UsetheTimerorResetbuttonstoadjustthe
VMGresponsetotherequiredlevel.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheSpeedandTripbuttons
atthesametimeforapproximately2seconds.
EnablinganddisablingBoatShowMode
FromtheUserCalibrationMenuAccesspage:
1.PresstheSpeedbuttonuntiltheBoatShow
Modepageisdisplayed(3pressesfromUser
CalibrationMenuAccesspage).
D12479-2
Spe ed
2.UsetheTimerandResetbuttonstoswitchboat
showmodeOnandOff(default).
SelectingOnwillputthedisplayintoboatshow
mode.
Note:Boatshowmodeisonlysuitablefor
demonstrationpurposesandshouldNOTbeused
whilstyourvesselisinuse.
Note:T oexittheDealerCalibrationpagesatany
time,pressandholdtheSpeedandTripbuttons
atthesametimeforapproximately2seconds.
Resettingthedisplaytofactorydefaults
FromtheUserCalibrationMenuAccesspage:
1.PresstheSpeedbuttonuntiltheFactory
Defaultspageisdisplayed(4pressesfromUser
CalibrationMenuAccesspage).
D12480-2
Spe ed
2.Toresetthedisplaytofactorydefaultsettings:
i50Speed
51

Table of Contents