EasyManua.ls Logo

Raymarine SPX 10 - Seatalk Connection

Raymarine SPX 10
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OFF
ON
FLUXGATE
FAULT
S LEEP
FAULT
, 3 AMP, 3 AMP
NMEA
0
V
10
V
0
V
0
V
RUDDE R J ET SIGNA L
CAN
CAN,1 AMP
0
V
10
V
2
1
3
4
D10 458 -3
1.SeaTalk
ng
powerswitch.
2.Coursecomputerconnectorpanel.
3.SPXtoSeaT alk
ng
spurcable.
4.SeaTalk
ng
backbone.
Note:Theconnectionatthebackbonemaybe
intoaT-pieceor5–wayconnector(notshown).
SeaTalk
ng
powerswitch
Thecoursecomputercanprovidepowertothe
SeaTalk
ng
backbone.Thiswillprovidepowertocertain
equipmentconnectedtothebackbone(e.g.ST70pilot
controllerandinstruments).
SettheSeaT alk
ng
powerswitchontheconnectorpanel
totheappropriateposition:
ONThecoursecomputerwillsupplypowertothe
SeaTalk
ng
backbone.Ensurethattherearenoother
powerfeedsconnectedintothebackbone.
OFFThecoursecomputerwillnotsupplypower
theSeaTalk
ng
backbone.Ensurethatthereisa
separatepowerfeedtotheSeaT alk
ng
backbone.
Important:Usecorrectfuse.Thefusesupplying
theSeaT alk
ng
systemMUSTberatedasperthe
valueshownontheconnectorpanel.
3.8SeaTalkconnection
TheSPXcoursecomputerhas2SeaT alkconnectors
available.Itisrecommendedthat1oftheseisreserved
forconnectiontotheprimaryautopilotcontroller.
ExampleSeaTalkautopilot
SeaTalk
SMARTPILOT
D10 468 -2
2 3
1
1.SPXcoursecomputer.
2.Helmpositionwithprimaryautopilotcontroller(on
dedicatedSeaT alkconnection).
3.Helmpositionwithsecondaryautopilotcontroller
andinstrument(s).
SPXtoSeaTalkconnection
UseaSeaTalkcable.DependingupontheSeaT alk
cableobtained,youmayneedtoremovetheconnector
fromoneendtorevealthecablecores.
SeaTalk
D10 459 -3
OFF
ON
FLUXGATE
FAULT
SLE EP
FAULT
3
1
2
Cablesandconnections23