EasyManua.ls Logo

Raymarine SPX 10 - SPX-SOL Connections Overview; Power and Drive Cables

Raymarine SPX 10
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.3SPX-SOLconnections
overview
GRO UND
3029 -632-E
PO WER
PO WER, 1 5 AMP
12V
OFF
ON
24V
FLUXGATE
RUDD ER
BYPASS
FAULT
SLE EP
FAULT
, 3 AMP, 3 AMP
NMEA
Rayma rine Limite d
PO WER
SO LENO ID SO LENO ID
A B
D10 446 -2
8 9 10 11
4 5 6 72 31
1.SeaTalk
ng
2.NMEA0183in/out(4800baudrate)
3.Sleepswitchconnection
4.Powerin
5.SolenoidAandBdrive
6.SolenoidAandBreturn
7.RFground
8.SeaTalk
9.Fluxgatecompass
10.Rudderpositionsensor
11.Bypassvalve
3.4Poweranddrivecables
Whendeterminingthecablerequiredforthepower
anddriveconnectionsitisnecessarytoconsiderthe
combinedcablelengthofbothconnections.
A
B
D10 454 -2
123
1.Coursecomputer
2.Powersupply/distributionpanel
3.Driveunit
Poweranddrivecableselection
Drive
Supply
voltage
Max.
length
(A+B)Cablesize
Type0.5
hydraulic
pump
0–7m
(0–23ft)
2.5mm
2
(14AWG)
Type1
drive
CRpump
(SPX-SOL
only)
12V
7–10m
(23–32.8ft)
4mm
2
(12AWG)
Drive
Supply
voltage
Max.
length
(A+B)Cablesize
0–5m
(0–16.4ft)
6mm
2
(10AWG)
12V
5–7m
(16.4–23ft)
10mm
2
(8AWG)
0–3m
(0–9.8ft)
4mm
2
(12AWG)
3–5m(9.8
–16.4ft)
6mm
2
(10AWG)
Type2drive
24V
5–10m(16
.4–32.8ft)
10mm
2
(8AWG)
12V0–5m
(0–16.4ft)
10mm
2
(8AWG)
0–5m
(0–16.4ft)
6mm
2
(10AWG)
Type3drive
24V
5–7m
(16.4–23ft)
10mm
2
(8AWG)
Important:Useofanincorrectpowercablesizewill
reducethepowersuppliedtothedriveunitandcould
causeyourautopilottomalfunction.Ifindoubt,use
aheaviergaugecable.
Poweranddriveconnection
Powerconnection
Powertothecoursecomputermustbefroman
appropriatelyfusedandratedsupply.
Cablesandconnections19

Other manuals for Raymarine SPX 10

Related product manuals