38 ST60 Tridata Instrument Owner’s Manual
9. Carry out a second calibration run (see
sheet 2
of the
Speed calibration
flow chart), using the procedure described above in steps 4 to 8.
Note:
At the end of this second run, the text End alternating with the new calibration fac-
tor is displayed at the bottom of the screen.
10. Press the speed key to leave distance calibration and return to the Instru-
ment status screen.
from Speed
calibration - sheet 1
At the start of the
outward cal run
press
At the start of
the return cal
run press
At the end of the
outward cal run
press
At the end
of the return
cal run
press
Carry out the
outward leg of
the second
cal run
Carry out the
return leg of
the second
cal run
Press
to store cal factor
speed
Press
Speed calibration - sheet 2
D4421-1
to return to
Instrument status display
(Intermediate calibration)
depth
speed
speed
speed
speed
depth
Alternating
and
81040_5.book Page 38 Monday, February 20, 2006 2:39 PM