23
There happens the malfunction at the charger circuit by any reason.
The processor detects the voltage is lower than you set at Lithium
program. Please check the cell count of the battery pack.
The processor detects the voltage is higher than you set at Lithium
program. Please check the cell count of the battery pack.
The voltage of one of the cell in the Lithium battery pack is too low.
Please check the voltage of the cell one by one.
The voltage of one of the cell in the Lithium battery pack is too high.
Please check the voltage of the cell one by one.
There are bad connection at the individual connector.
Please check the connector and cables carefully.
The internal temperature of the unit goes too high.
Cool down the unit.
The processor can not continue to control the feeding current by any
reason. The unit needs to be repaired.
The battery balance port or the power line to connect incorrect.
-
19
-
There happens the malfunction at the charger circuit
by any reason .
The processor detects the voltage is lower than you
set at Lithium program. Please check the cell count of
the battery pack.
The processor detects the voltage is higher than you
set at Lithium program. Please check the cell count of
the battery pack.
The voltage of one of the cell in the Lithium battery
pack is too low. Please check the voltage of the cell
one by one.
The voltage of one of the cell in the Lithlum battery
pack is too high. Please check the voltage of the cell
one by one.
There are bad connection at the individual connector.
Please check the connector and cables carefully.
The internal temperature of the unit goes too high.
Cool down the unit.
The processor can not continue to control the feeding
current by any reason. The unit needs to be repaired.
The battery balance port or the power line to
connect incorrect.
Battery Pack IR
0mΩ
1: -- - --- --- mΩ
4: -- - --- --- mΩ