2.3.3 Adjust Nozzle Flow Rate and Reference Pressure
Cal Mode 1 ( + Power-up ) - Channel 4: Default - see table 1).
This channel allows you to set the default nozzle and set the correct nozzle
flow rate for a given reference pressure following a jug test.
1. Press the '+' / '-' keys to select the appropriate nozzle. The display will show
'nn A' to 'nn I'
2. For the selected nozzle (A to I), press and hold the key. After 5 seconds
the default pressure is shown e.g. 'P3.00'. This is the reference pressure set
for the jug test.
3. To adjust the reference pressure, continue holding the key, and adjust
the value using the '+' and '-' keys.
4. Release the key to confirm the entry.
Press again within 5 seconds to display the flow rate e.g. 'Fx.xx'. This is the
nozzle flow rate measured from the jug test.
5. To adjust the flow rate, continue holding the key, and adjust the value
using the '+' and '-' keys.
6. Release the key to confirm the entry.
Table 1
User-defined
Nozzle
Default
Flow Rate
(l/min @ 3
bar ref.)
User-defined nozzle
description
Flow
Rate
(l/min)
Reference
Pressure
(bar)
A 0.4
B 0.6
C 0.8
D 1.0
E 1.2
F 1.6
G 2.0
H 2.4
I 3.2
NOTE: You can also select the default nozzle and adjust the flow rate during startup
so you don't have to use this channel.