SPRAYMASTER 200
9
2.1.4 Set No. of Nozzles per Section
Cal Mode 1 ( + Power-up ) - Channel 6: Default = '0'
(i) For single section sprayers fitted with a simple cutout switch, the number
displayed is the total no. of nozzles for the boom.
(ii) If connecting an ACI module into the sprayer switchbox, switch on one
section at a time and then set the number of nozzles for that section. Repeat
for each section in turn.
If none or more than one section is switched on, the display will show "1SEC"
and you can't programme the no. of nozzles.
2.1.5 Nozzle Spacing
Cal Mode 1 ( + Power-up ) - Channel 2: Default = '0.5 (m)'
Set the nozzle spacing as required.
2.2 Select Pressure or Flow-based Regulation
Cal Mode 2 ( + Power-up ) - Channel 1: Default = 'Pres'
The Spraymaster can be configured as follows,
(i) Pressure sensor input only (default setting).
The display will simply show 'PrESS'. A pressure gain setting of >0 (Cal 3,
Channel 2) enables the pressure sensor input. Refer to section 2.2.2 for
pressure sensor calibration.
NOTE: With the pressure sensor input enabled, you are prompted to select/adjust
the nozzle type on normal startup.
(ii) Flow sensor input only (you can programme up to 6 configurations for
different flow sensors).
The display will simply show 'turb'. You can programme the instrument with
up to 6 different flow sensor factors for sensors A to F. This is a not likely to
be a common requirement and is intended for more specialist applications
such as vineyard/orchard sprayers. A flow sensor factor of >0 set for one or
more sensors A to F enables the flow sensor input.
NOTE: If more than one sensor factor is set >0, you are prompted to select/adjust
the flow sensor on normal startup.