Beijing Reci Laser Technology Co., Ltd
User Guide for Single Module Fiber Laser
Table 2.1 the operation conditions for the single module series lasers
Flat, upright, no vibration and impact
Electromagnetic Environment
Avoid too strong electromagnetic interference, which
may lead to false alarm of laser
QBH and even the whole machine need deionized water
to prevent scaling.
At the absence of deionized water, pure water for
drinking can be used. When the ambient temperature is lower
than 0
℃
, antifreeze (30% volume ratio for alcohol) needs to
be added to the cooling water.
Note:
(1) Never use the tap water or other cooling water with high ion concentration.
(2) The cooling water shall be replaced timely to prevent microorganism and
ions growth.
(3) It is very easy to be damaged when the QBH getting scaling, and there is no
warranty in this case.
(4) The output of the laser is connected with the cable. Please check the end
surface of the quartz head carefully to prevent dust or other pollution.
Lens-cleansing paper must be used when cleaning is necessary.
(5) Never installing the laser output with the processing system when the
equipment is power on.
(6) The protective glasses should be worn all the time.