Dichiarazione CE di conformità
EC declaration of conformity
Torino, 18/03/2016
REER SpA
via Carcano 32
10153 Torino
Italy
dichiara che le barriere fotoelettriche EOS4 sono Dispositivi Elettrosensibili di Sicurezza (ESPE) di :
Tipo 4 (secondo la Norma EN 61496-1/A1:2008; IEC 61496-2:2006)
SIL 3 (secondo la Norma IEC 61508-1:1998; IEC 61508-2:2000; IEC 61508-3:1998; IEC 61508-4:1998)
SILCL 3 (secondo la Norma IEC 62061:2005)
Cat.4 - PL e (secondo la Norma EN ISO 13849-1:2008)
declares that the EOS4 photoelectric safety barriers are :
Type 4 (according the Standard EN 61496-1/A1:2008; IEC 61496-2:2006)
SIL 3 (according the Standard IEC 61508-1:1998; IEC 61508-2:2000; IEC 61508-3:1998; IEC 61508-4:1998)
SILCL 3 (according the Standard IEC 62061:2005)
Cat.4 - PL e (according the Standard EN ISO 13849-1:2008)
Electro-sensitive Protective Equipments (ESPE)
realizzati in conformità alle seguenti Direttive Europee:
complying with the following European Directives:
2006/42/EC "Direttiva Macchine"
"Machine Directive"
2014/30/EU "Direttiva Compatibilità Elettromagnetica"
"Electromagnetic Compatibility Directive"
2014/35/EU "Direttiva Bassa Tensione"
"Low Voltage Directive"
e alle seguenti Norme: /and to the following Standards:
EN 50178: 1997
EN 55022: 2006
e sono identiche all'esemplare esaminato ed approvato con esame di tipo CE da:
and are identical to the specimen examined and approved with a CE - type approval by:
TÜV SÜD Rail GmbH Ridlerstrasse 65 D-80339 Muenchen Germany
Carlo Pautasso Simone Scaravelli
Direttore Tecnico Amministratore Delegato
Technical Director Managing director

Other manuals for Reer EOS4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Reer EOS4 and is the answer not in the manual?

Reer EOS4 Specifications

General IconGeneral
Power Supply24 VDC ±20%
Resolution14 mm
Safety CategoryType 4
Operating Temperature+55 °C
Protection RatingIP65
Detection CapabilityOpaque objects
ConnectionM12 connector
Response Time≤ 20 ms
Outputs2 x safety outputs (OSSDs)