EOS4 SAFETY LIGHT CURTAIN
8540733 • 23/03/2016 • Rev.17 7
English
Master/Slave Positioning
In addition to standard models (that can be positioned either horizontally or vertically),
EOS4 can be purchased in a MASTER/SLAVE configuration. This configuration comprises
two (or three) pairs of light curtains in which the two (or three) Emitters and the two (or
three) Receivers are connected in series.
Figure 3 Examples of Master/Slave configurations
The connection cable between the master and slave may be up to 50 metres in length.
This characteristic permits configuration of an application with two light curtains
positioned one at the front and one at the rear of the dangerous machine, with a single
connection towards the machine power and control circuits (Figure 4).
Figure 4 - Example of Master/Slave application with mechanical guards
MASTER
MASTER
SLAVE
SLAVE2
SLAVE

Other manuals for Reer EOS4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Reer EOS4 and is the answer not in the manual?

Reer EOS4 Specifications

General IconGeneral
Power Supply24 VDC ±20%
Resolution14 mm
Safety CategoryType 4
Operating Temperature+55 °C
Protection RatingIP65
Detection CapabilityOpaque objects
ConnectionM12 connector
Response Time≤ 20 ms
Outputs2 x safety outputs (OSSDs)