36 REFUsol 08K ... 23K REFU Elektronik GmbH
5.2.2
Accepting the Country Code
To be certain, you will be asked whether you wish to accept the country code. After accepting the country
code it can only be changed within 40 hours.
Only confirm the country code if you are absolutely sure it is correct.
If you are not sure, press
ESC
to cancel your selection and correct the selection.
If the country code is to be accepted, then confirm with
OK
.
A restart then takes place:
"ERROR" and "GROUND FAULT" status LEDs flash red alternately.
5.3
Device Start
Solar modules are irradiated with sufficient sunlight.
Country code is set.
Time and date is set.
The following procedure follows:
Self-test All status LEDs are lit for approx. 6 seconds
Check “START” status LED lights orange.
Activation “START” status LED lights orange/LED “ON” flashes green.
Feed in “ON” status LED lights green/normally all other status LEDs are off.
Set Country to
AR-N 4105 ?