Troubleshooting 63
Error List
REFUsol 100K
982059/02
2020-11
EnglishDeutsch
A0196
DC voltage too high The unit was shut down after the DC input
voltage exceeded the unit's rated voltage.
Measure DC voltage.
Set the DC voltage value indicated on the
type label.
Acknowledge the error.
A0197
DC Overvoltage DC overvoltage occurred.
Measure DC voltage.
Set the DC voltage value indicated on the
type label.
A0198
DC asymmetry DC voltage unbalanced. No action necessary.
A0199
DC voltage jump An unacceptable DC voltage peak has occur-
red. The unit is in a safe mode for a short time
to prevent damage to property.
No action necessary.
A019A
DC part timeout Timeout in DC part component monitoring oc-
curred.
No action necessary.
If the error still occurs, contact REFU Ser-
vice.
Error Code Message Description Instructions