11
Cosmetic Care & Maintenance
CARBON MONOXIDE DETECTORS
We strongly recommend that you fully acquaint yourself
with the total operation of the carbon monoxide detector
since it does measure accumulated levels of CO. Normal
maintenance should include frequent checking including
the green power light glowing with the warning indicator
and audible horn off.
Each detector should be returned to the manufacturer
each year for recertification. Refer to the owner’s
document box for more information.
The CO detectors are normally located in the berth areas
of the vessel.
TYPICAL CO DETECTOR
From Water Heater
Check Valve
SHOWER SUMP PUMP (TYPICAL)
From AC Condenser
From Water Heater
Drain Valve
From Shower
From Shower Sump Pump
To Manifold Collector
The shower sump pump shown above is used to collect
used water waste from the sinks or the shower itself. After
the liquid reaches a designated height, the sump pump
energizes through a float switch and exits waste to a
manifold then overboard. Periodically check the sump
pump grate for debris such as hair and soap build up.
Check to make sure the automatic float operates freely at
all times. Also, clean out the box with a bleach/water
solution as needed to kill bacteria. You can back flush
using the bleach/water procedure.