4
Chapter 10
FRESH WATER SYSTEM:
1. Turn on the fresh water pump switch.
2. Open all faucets including transom shower and allow
tank to empty.
3. Drain the water heater; shut off water pump switch.
4. Mix nontoxic antifreeze with water in accordance with
the manufacturer’s recommendations.
5. Pour solution into the fresh water tank.
6. Turn on fresh water pump switch.
7. Open each cold water faucet one by one beginning
with the one furthest away from the tank and purge
the system until a steady stream flows from the faucet.
Then close the faucet.
8. Repeat step 7 for hot water faucets.
9. Shut off water pump switch.
10. Pour a quart of nontoxic antifreeze into shower
drain. Run the shower pump until a steady stream
flows from the discharge fitting.
11. Leave at least 2 gallons of antifreeze solution in the
holding tank during storage.
WASTE/TOILET SYSTEM:
1. Pump out waste holding tank, flush the tank with
fresh water and pump out again.
2. With nontoxic propylene glycol type antifreeze in
the fresh water tank, operate head until antifreeze
flows into bowl of head.
3. Operate macerator until antifreeze has a steady flow
coming from the discharge fitting. Pour nontoxic
antifreeze solution in head and flush head as needed
to winterize macerator pump.
4. Leave at least 2 gallons of antifreeze solution in the
holding tank during storage.
5. For further information see the toilet owner’s manual
in the document pouch
ELECTRIC TOILET
1. Operate the toilet in the dry bowl mode to evacuate
as much water as possible. Drain the remaining water
from the base by removing the base plug or sponge
from bottom of bowl.
2. When filling the holding tank by pumping it through
the toilet, use only ethylene glycol based antifreeze
not petroleum based anti-freeze.
There are several methods of winterization that can be
used with your AC unit. Use only 50/50 non-polluting
biodegradable antifreeze/water solution. See your AC
manual in your owner’s pouch for more information or
call your Regal dealer.
1. Open seacock and allow water to drain if boat
is out of the water. Clean out the seacock and
close it.
2. Open top of strainer and fill with antifreeze
solution.
3. Operate air conditioning pump refilling sea
strainer with antifreeze as the level goes down.
4. Continue to operate pump until antifreeze
flows out of thru-hull fitting.
5. Shut off air conditioning pump and install the
seawater strainer top.
AIR CONDITIONING: