69
Systems
Using Later Style Toilet-
To use the on board toilets rst make sure the forward
and aft 12 volt breakers are activated at the main control
panel. If using dockside water make sure water is owing
from the marina spigot.
The wall control switch is used to add water to the bowl
and to ush the toilet. Select cycle information is noted
below. For more complete information, refer to the toilet
vendor information located in the information packet.
1. To add water (est. 17 ounces each cycle ) to the bowl
press the add water button momentarily and release. The
system prevents over lling the bowl.
2. To ush the bowl press the ush button momentarily
and release. The attached bowl motor will macerate the
waste and ush it. The cycle ends with a small amount of
water being added to the bowl to help prevent odors. This
completes the minimal water usage ush cycle.
Wall Control Panel Blue Backlighting Description:
The holding tank icon in the lower right hand corner
of the control panel is not lighted. Toilet system is off
or not receiving power.
The holding tank icon is normally green. This means
the holding tank is less than full.
The holding tank icon is red. The holding tank is full
or near full with the ush lockout (prevents Flush
operation when holding tank is full) activated.
Tank icon ashes
Sleep mode (non-use for 8 hours) causes the lights to
go out. Pushing the ll or ush button momentarily
will return lighting cycle.
Single Flush Override of Flush Lockout
1. If the holding tank is full the ush lockout cycle will
not allow the bowl to be ushed and the ush button will
be lighted red.
2. For emergency use only the ush button can be held for
8 seconds and a ush will occur. This can be accomplished
because the full sensor connected to the holding tank
is usually placed a bit below the actual full capacity of
the tank. Flushing more than 5 times using the override
feature may force waste into plumbing system. Regal is
not responsible for damage to equipment, or injury or
death due to over ow of waste due when ush lockout
is overridden. Again, refer to toilet vendor information
in the owner’s information packet.
HOLDING
TANK
CAUTION
!
POSSIBLE OVERFLOWING
OF THE WASTE HOLDING TANK
CAN OCCUR DUE TO USING
THE SINGLE FLUSH OVER-RIDE FUNCTION.
FOR EMERGENCY USE ONLY.
TYPICAL WALL SWITCH
FLUSH
LOCKOUT
ADD
WATER