61
Cosmetic Care & Maintenance
Volvo IPS- Engine Circuit Braakers
There are circuit breakers on the engine to protect the
engine and drive unit wiring circuits. The circuit breakers
will shut the power down if an overload occurs.
Symptoms of a circuit breaker problem would be not being
able to start the engine or instrumentation not functioning
while running the engine or the EVC system failing.
It is important to nd the cause of the overload before
the circuit breaker is reset. The circuit breaker can be reset
by pushing in on it.
Number 1 is the outdrive breaker location and number 2
is the engine breaker location.
WARNING
!
TO PREVENT POSSIBLE FIRE
AND/ OR ENGINE DAMAGE
DISCONNECT ALL ELECTRICAL POWER BE-
FORE PERFORMING
ELECTRICAL MAINTENANCE.