Electric heating element (heating coil)
Irrespective of which operating mode has been set,
the heating coil can be activated. In order to do so,
confirm the "Electric heating element" key (D). The
symbol appears on the display to indicate that the
heating coil is active. Upon reaching the target
temperature, the heating coil switches of
f automati-
cally.
Fig. 29: Electrical heating element - HP is on
Fig. 30: Electrical heating element - HP is off
NOTES
1. The auxiliary heater must also be sepa-
rately enabled automatically as required in
parameter level "r" via parameters "r04, r05,
r06" (see
Ä
on page 49, no. 41 to 54).
The auxiliary heater is inactive unless the
values are adjusted.
2. The auxiliary heater is always enabled
according to the stored parameters "r04" to
"r10", irrespective of the intake temperature!