RH850/F1x StarterKit V3 User Manual
R01UH0724ED0120 Page 18
January 2018
4.2.1.2 Power supply measurement
The current which is consumed by MCU can be measured by using J5. The appearance of J5 is
different on the two Release Version. Please find below a description of the different versions.
RH850/F1L and RH850/F1K:
J5 MCU power
measurement
1-2 REGVCC power supply (5 V)
3-4 EVCC, AV0REF, A1VREF power supply (5 V)
5-6 BVCC (5 V)
7-8
(not used)
Table 7. RH850/F1L and RH850/F1K MCU power measurement on Release Version EEAS-0401-003-01
Note for RH850/F1L and RH850/F1K
J5 MCU power
measurement
1-2 REGVCC power supply (5 V)
3-4 Total MCU power supply (5 V)
Table 8. RH850/F1L and RH850/F1K MCU power measurement on Release Version EEAS-0401-002-01
RH850/F1H and RH850/F1KM-S4:
J5 MCU power
measurement
1-2 REGVCC power supply (5 V)
3-4 EVCC, AV0REF, A1VREF power supply (5 V)
5-6 BVCC (3,3 V)
7-8
(not used)
Table 9. RH850/F1H MCU power measurement on Release Version EEAS-0401-003-01